Universal data logger Titan S8

Photo: Universal data logger Titan S8
Photo: Universal data logger Titan S8
Photo: Universal data logger Titan S8
Photo: Universal data logger Titan S8
Photo: Universal data logger Titan S8
Photo: Universal data logger Titan S8
Photo: Universal data logger Titan S8
Photo: Universal data logger Titan S8
Photo: Universal data logger Titan S8
Photo: Universal data logger Titan S8

Titan S8 is a state-of-the-art 8-channel data acquisition system. Capable of simultaneously measuring and recording temperature, voltage, current, pulse and frequency, the Titan S8 datalogger is a one-stop solution for any industrial engineer, quality assurance, metrologist or mechanic.

The datalogger is supplied with a factory calibration certificate ISO 17025.

The MadgeTech Titan S8 is a portable, multi-use industrial data logger with eight probe channels and a user-friendly touchscreen interface. This versatile logger supports thermocouple, RTD or thermistor probes to measure current, voltage, temperature and pulse in real time. This adaptability and power make Titan S8 the perfect companion for any industrial engineer, quality assurance professional, compliance officer or automotive technician.

Part of the Titan S8’s might comes from its independence. Unlike many data loggers, the Titan is a complete, all-in-one solution that does not require a PC or any downloaded software for operation. This means the device is truly ready for use at a second’s notice and will never leave users waiting because of upload times or a frustrating software interface.


0-24 МА

Resolution ........................ 0.0001 mA

Accuracy .......................... ±0.024 mA

Input Impedance ............... 30 Ω

FREQUENCY / PULSE

Maximum Count .............. 4,000,000,000

Maximum Frequency ........ 20 KHz

Input Signal .................... 0 V - 12 V

Input Impedance  ............ 58 KΩ

TEMPERATURE PT-100 (2-WIRE RTD)

Resolution ................. 0.01 °C

Accuracy ................... ±0.1 °C

Range ...................... -200 °C ... +400 °C

0-100 MV

Maximum Voltage .............. 3.0 V

Resolution ........................ 0.001 mV

Accuracy .......................... ±0.1 mV

Input Impedance ............... 1 GΩ

TEMPERATURE NTC-1 (2252)

Resolution ....................... 0.01 °C

Accuracy ........................ ±0.50%

Range ............................ -25 °C ... +150 °C

TEMPERATURE PT-100 (3-WIRE RTD)

Resolution ................. 0.01 °C

Accuracy ................... ±0.1 °C

Range ....................... -200 °C ... +400 °C 

0-10 V

Maximum Voltage ............. 25 V

Resolution ....................... 0.001 V

Accuracy ......................... ±0.01 V

Input Impedance .............. 1 GΩ

TEMPERATURE NTC-2 (10K)

Resolution ....................... 0.01 °С

Accuracy ......................... ±0.50%

Range  ............................ -25 °C ... +150 °C

TEMPERATURE PT-100 (4-WIRE RTD)

Resolution .................. 0.01 °C

Accuracy .................... ±0.1 °C

Range ........................ -200 °C ... +400 °C

   


GENERAL CHARACTERISTICS
Operating environment

0 °C ... +50 °C, 0 %RH ... 95 %RH non-condensing

Memory

100,000,000 readings; 1 GB.

Channels

8 (Temperature, Current, Frequency, Voltage, Pulse)

Material

PC / ABS Enclosure, TPE Protective Boot

IP rating

IP20

Battery life

10 hours continuous use

Dimensions